Анализ на диагностично значими еритроцитни цитограми, получени с хематологичен анализатор ADVIA 2120

dc.contributor.authorВелизарова/Velizarova, М./M.
dc.contributor.authorЯчева/Yacheva, Т./T.
dc.contributor.authorЦачев/Tzatchev, К./K.
dc.date.accessioned2015-09-14T10:47:52Z
dc.date.available2015-09-14T10:47:52Z
dc.date.issued2012-06
dc.descriptionАдрес за кореспонденция: Д-р Милена Велизарова, Катедра по клинична лаборатория и клинична имунология, МУ, ул. „Св. Г. Софийски” № 1, 1431 София, тел. 02 92-30-916, e-mail: mvelizarova@abv.bg ***** Address for correspondence: Milena Velizarova, M. D., Department of Clinical Laboratory and Clinical Immunology, MU, 1, Sv. G. Sofiyski Str., 1431 Sofia, tel. +359 2 92-30-916 e-mail: mvelizarova@abv.bgen_US
dc.description.abstractРезюме: Лабораторният персонал обикновено е отлично запознат с интерпретацията на числените резултати, получени със съвременните хематологични анализатори, докато сложните на пръв поглед цитограми и хистограми остават игнорирани. Целта на това проучване е установяване и интерпретация на типични, диагностично значими еритроцитни (RBC) цитограми при изследване на пациенти с различни заболявания на червения ред. Анализирани са числените и графичните данни, получени при изследване на 946 (342 здрави и 620 с хематологично заболяване) пациенти с помощта на автоматичен хематологичен анализатор ADVIA 2120 (Siemens Healthcare Diagnostics Inc). Направена е оценка на вида на разпределение на еритроцитния облак според обема (V) и хемоглобинова концентрация (HC) на еритроцитите при желязодефицитна анемия, хетерозиготна и хомозиготна таласемия, мегалобластна и немегалобластна макроцитоза, двойнодефицитна анемия, посттранфузионни промени. Еритроцитните цитограми и другите автоматични хематологични резултати са дискутирани в корелация с клиничните и биохимичните данни при изследваните пациенти. ***** Summary: The laboratory staff is familiar with the basic interpretation of numerical results, obtained by the automated hematology analyzers, but seemingly complex cytograms and histograms are often ignored. The purpose of this study was to identify characteristic red cell (RBC) cytogram patterns in various hematological conditions. Numerical and graphical results of the RBC data in 946 (342 healthy individuals and 620 patients with hematological diseases/conditions) were analyzed by the automated hematology analyzer ADVIA 2120 (Siemens Healthcare Diagnostics Inc). The graphical pattern of red cell distribution according to RBC volume/hemoglobin concentration (V/HC) was evaluated in iron deficiency anemia, heterozygous and homozygous thalassemia, megaloblastic and nonmegaloblastic macrocytosis, dual deficiency anemia, and post-transfusion findings. Red cell cytograms and other automated results were correlated with the clinical profiles and biochemical data.en_US
dc.identifier.citationМ. Велизарова, Т. Ячева и К. Цачев. Анализ на диагностично значими еритроцитни цитограми, получени с хематологичен анализатор ADVIA 2120 - Медицински преглед, 48, 2012, № 3, 50-54.en_US
dc.identifier.issn1312-2193
dc.identifier.urihttp://hdl.handle.net/10861/777
dc.language.isootheren_US
dc.publisherЦентрална медицинска библиотека, МУ София / Central Medical Library, MU Sofiaen_US
dc.subjectавтоматични хематологични анализатори, Advia 2120, цитограми, RBCen_US
dc.subjectautomated hematology analyzers, Advia 2120, cytogram, RBCen_US
dc.titleАнализ на диагностично значими еритроцитни цитограми, получени с хематологичен анализатор ADVIA 2120en_US
dc.title.alternativeAnalysis of diagnostic red cell cytograms, generated by the ADVIA 2120 hematology analyzeren_US
dc.typeArticleen_US
Файлове
Original bundle
Показани 1 - 1 от 1
Зареждане...
thumbnail.default.alt
Име:
Velizarova_et-al_med-3-2012.pdf
Размер:
213.92 KB
Формат:
Adobe Portable Document Format
Описание:
License bundle
Показани 1 - 1 от 1
Зареждане...
thumbnail.default.alt
Име:
license.txt
Размер:
28 B
Формат:
Item-specific license agreed upon to submission
Описание: